Takaitaccen Bayani:

Gina a cikin tsarin ozone, tsaftacewa ta atomatik, hana kamuwa da cuta.
Preheating mai hankali, bankwana zuwa bushe da sanyi.


imgs samfurin cikakken bayani

Cikakken Bayani

微信图片_20201223111023微信图片_20201223111015微信图片_20201223111011

Bayani

Gida Non-invasive inji ventilation (NIV) shi ne kowane nau'i na goyon bayan iska ba tare da endotracheal tube.An yi amfani da NIV a asali a cikin marasa lafiya tare da rashin daidaituwa na numfashi mai tsanani ko rashin lafiyar cututtuka na numfashi na kullum, a matsayin madadin tube na endotracheal.

Samun iska na gida wanda ba mai cutarwa ba (NIV) yana nufin samar da tallafin iska ta hanyar jirgin sama na majiyyaci ta hanyar amfani da abin rufe fuska ko makamancin haka wanda shine babban kewayon musaya da aka tsara don amfani da gida da tashar jiragen ruwa da aka saba ginawa cikin abin rufe fuska.
  
Aikace-aikace
Ciwon hanci.Lokacin da kuke son barci , kuna iya samun rashin jin daɗi da wahalar yin barci, musamman a farkon farawa da jin daɗin claustrophobia ko damuwa.

Nassoshi masu kauri da ƙarin ma'ajiyar kitse a kusa da hanyar iska.Tsokoki masu annashuwa suna ɗaukar ƙarin sarari, kuma sakamakon haka, an toshe iska zuwa huhu.Tare da toshe hanyar iska, iska daga hanci da baki ba za su iya kaiwa huhu ba, kuma mutum yakan tashi yana haki yana shakewa.

 

Amfani
Gina a cikin tsarin ozone, tsaftacewa ta atomatik, hana kamuwa da cuta.

Preheating mai hankali, guje wa bushewa da sanyi.

Duban ainihin lokacin bayanan jiyya da yawa.

Akwatin ruwa cikakke an rufe shi da tushe mai dumama, hana zubewa da sauƙin tsaftacewa.

Yanayin AUTO CPAP, bisa ga toshewar iska, an zaɓi mafi kyawun matsa lamba ta atomatik tsakanin IPAP mafi ƙasƙanci da IPAP mafi girma don buɗe hanyar iska da inganta jin daɗin marasa lafiya.

AUTO Bi-level Mode, bisa ga katsewar iska, kewayon IPAP ta atomatik da kewayon EPAP suna ba da mafi kyawun matsa lamba biyu don buɗe hanyar iska yayin inganta jin daɗin haƙuri da haɓaka ta'aziyyar marasa lafiya.

 

Ƙayyadaddun bayanai

Samfura B1
Yanayin

CPAP ta atomatik

Mota Bilevel

Kewayon matsi

(cmH2O)

4-25
Daidaitaccen matsi ± 0.2 cm H2O
Max.Matsin Aiki 30 cm H2O
Lokacin ramp Minti 0 zuwa 45 (ƙara na mintuna 5)

COMF

rage matsa lamba

1-3 matakan
Humidification Matakan 1-5 (113 zuwa 185°F/23 zuwa 85°C
Lokacin tashi 1-4 matakan
Raba dare EE

Adana bayanai

iya aiki

8G kebul na USB
Nauyi 1.72 kg
Ma'ana matakin sauti ≤30 dB

 