ST-30H mai ba da iska mai cutarwa don amfanin asibiti

Takaitaccen Bayani:

Ƙananan rikice-rikice: NIV yana rage yawan yiwuwar rikitarwa ta hanyar 62% da kurakurai na magani da 50%.


imgs samfurin cikakken bayani

Cikakken Bayani

44 45

 

Bayani

Samun iska mara lalacewa (NIV) yana tallafawa numfashin mara lafiya ba tare da buƙatar intubation ko tracheotomy ba.NIV tana ba da ingantaccen magani tare da ƙarancin kamuwa da cuta da ingantaccen rayuwa a cikin marasa lafiya da gazawar numfashi

Samun iska mara lalacewa (NIV) tallafin iska ne da ake ba marasa lafiya ba tare da amfani da bututun endotracheal ba.Yana haifar da yuwuwar rikice-rikice na iskar injuna mai haɗari da ake gujewa.Hakanan yana taimakawa wajen isar da ingantaccen magani tare da rage tsawon zama a cikin ICU da ingantaccen damar rayuwa.

Aikace-aikace

Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar Cutar ta huhu: Yin amfani da iskar da ba ta da ƙarfi (NIV) don tallafa wa marasa lafiya a lokacin raunin rashin ƙarfi na numfashi na biyu zuwa ɓarna na cututtukan huhu na huhu yana da shaidar da ba ta da tabbas na fa'ida cikin sharuddan raguwar buƙatar intubation, tsawon asibiti. zama da mace-mace.

Mummunan gazawar numfashi: An ƙara yin amfani da iskar injuna mara lalacewa don gujewa ko kuma zama madadin intubation.Idan aka kwatanta da maganin jiyya, kuma a wasu lokuta tare da iskar injuna mai ɓarna, yana inganta rayuwa kuma yana rage rikice-rikice a cikin zaɓaɓɓun marasa lafiya tare da gazawar numfashi.

Mai tasiri

Fasahar AST-Premium za ta sa ido kan kowane numfashi guda ɗaya na marasa lafiya, amsa nan da nan don daidaita numfashin marasa lafiya ta hanyar jan hankali ta hanyar gano kwarara, matsa lamba da canza yanayin motsi.

 Fasaha-Saukar da kai ta atomatik tana ba likita sauƙi ba buƙatar saita hankali da hannu ba, da rage ƙarfin numfashi na majiyyaci.

- Haɓaka haɓaka: goyan bayan faɗakarwa ta atomatik da matakan 3 suna haifar da daidaitawar hankali.Ƙarƙashin hankalin abin da ke jawo shi ne, ƙarancin aikin da majiyyaci ke buƙatar yi don tayar da hankali, kuma mafi sauƙi na na'urar numfashi zai fara.

- Janye hankali: goyan bayan janyewar atomatik da daidaita matakin 3 na hankali.Ƙarƙashin hankali, ƙananan aikin da marasa lafiya ke buƙatar yi don cire na'urar iska, kuma mafi sauƙi shine cire na'urar.

Ƙayyadaddun bayanai

Siga

ST-30H

Yanayin iska

S/T, CPAP, S, T, PC, VAT

Oxygen maida hankali

21% ~ 100%, (ƙara da 1%)

Girman allo

5.7 inch launi allon

Waveform nuni

Matsi / kwarara

IPAP

4 ~ 30cm H2O

EPAP

4 ~ 25cm H2O

CPAP

4 ~ 20cm H2O

Ƙarfin magudanar ruwa

20-2500 ml

Ajiyayyen BPM

1 ~ 60 BPM

Lokacin ajiyewa

0.2 ~ 4.0S

Lokacin tashi

Darasi na 1 ~ 6

Lokacin ramp

0 ~ 60 min

Matsin lamba

Yanayin CPAP: 4 ~ 20cm H2O Wani yanayin: 4 ~ 25cm H2O

Saurin matsi

Darasi na 1-3

Timin maras lokaci

0.2 ~ 4.0S

Timax maras lokaci

0.2 ~ 4.0S

Saitin Ƙarfafawa

Auto, 1 ~ 3 matakin

Saitin Ƙarfafawa

Auto, 1 ~ 3 matakin

Kulle mai tayar da hankali

Kashe, 0.3 ~ 1.5S

Yawo na yanayin HFNC

N/A

Matsakaicin kwarara

210 l/min

Mafi girman diyya

90L/min

Hanyar ma'aunin matsa lamba

Bututun gwajin matsa lamba yana gefen abin rufe fuska

Ƙararrawa

Apnea | Cire haɗin kai | Ƙarfin ƙaramin minti | Ƙarfin ƙaramar ruwa | Ƙarfin wutar lantarki | Yawan matsa lamba | Ba a samun iskar oxygen | Yawan iskar oxygen mai yawa |Ƙarancin baturi|Batir ya ƙare

Saitin kewayon ƙararrawa na Apnea

0S, 10S, 20S, 30S

Saitin kewayon ƙararrawa na cire haɗin haɗin

0S, 15S, 60S

Bayanan sa ido na ainihi

Yawan iskar oxygen na yanzu|Tsarin tushen oxygen

Sauran saituna

Kulle allo|Nuna haske|Tafiya|Matsi|Waveform

Ajiyayyen baturi

awa 8